Instructions for use and maintenance
This manual is owned by GEA Niro Soavi Any reproduction, even partial, is prohibited.
01C100-1C0
GEA Niro Soavi
13
All parts shall be properly packed to avoid any damage in transit, and accompanied by:
• reference to the purchase order;
• machine serial number;
• part code number;
• detailed description of the defect and how it was discovered;
• authorization module to the document completed and approved.
All parts recognized to be under guarantee are delivered ex works; replaced parts are the property
of
GEA Niro Soavi
and shall be returned ex works.
1.3.2 Testing
Before shipment all of our machines are accurately tested at
GEA Niro Soavi
premises by qualified
personnel through operational tests which simulate the normal working conditions.
Through the operational tests - run with cold water - it is possible to verify the actual performance
of the machine against the design data, the calibration of safety, control and check devices, the
conditions of any seals, as well as the noise and vibration-free operation of the machine and the
parameters introduced in any programmable instruments or equipment that might be used.
To test the performance of the machine (flow rate with the maximum operating pressure allowed,
noise level, electric absorption) the machine is run with water at a temperature of approximately 20
°C, so it is possible to verify the deviation of the machine’s actual flow rate compared to the rated
value ± 5% with product, according to the different temperatures and viscosity of the product treated.