Designation
Description
Control top T.VIS M-20, M-15, A-15, P-15
-20 to +55 °C (-4 to +131 °F)
Control top E-20
Ambient temperatures according to the specific
values stated for the gas or dust ignition protec-
tion
Product temperature and operating temperature
Dependent on the seal material, see
ance and permitted operating temperature of the
sealing materials
Designation
Description
Air hose
●
Metric
Material PE-LD
Outside Ø 6 mm
Inside Ø 4 mm
●
Inch
Material PA
Outside Ø 6.35 mm
Inside Ø 4.3 mm
●
Control air
acc. to ISO 8573-1
●
Solid particle content:
Quality class 6
Particle size max. 5 µm
Particle density max. 5 mg/m
3
●
Water content:
Quality class 4
max. dew point +3 °C
If the unit is used at higher altitudes or at low am-
bient temperatures, the dew point must be adap-
ted accordingly.
●
Oil content:
Quality class 3
preferably oil free
max. 1 mg oil to 1 m
3
air
Control air pressure
6 bar (87 psi), max. 8 bar (116 psi) configuration
with standard drive
Alternative combinations of product pressure and
control air pressure on request
Special model: min. 4.8 bar, max. 6 bar
Pneumatic support: spring side max. 6 bar
28 / 128 - 3.2 Technical data
0000000607 - 002 - EN-GB
Summary of Contents for ECOVENT
Page 6: ...6 128 Table of Contents 0000000607 002 EN GB...
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 128...
Page 12: ...12 128 1 4 Declarations of conformity 0000000607 002 EN GB...
Page 20: ...20 128 2 10 Emergency measures 0000000607 002 EN GB...
Page 40: ...40 128 5 5 Checking the pneumatic connection 0000000607 002 EN GB...
Page 44: ...44 128 7 3 Shutdown 0000000607 002 EN GB...
Page 106: ...106 128 9 7 Maintenance 0000000607 002 EN GB...
Page 120: ...120 128 12 2 Spare parts list 0000000607 002 EN GB...
Page 127: ...13 2 List of abbreviations 127 128...