9.7.3 Lubricating seals and threads
Prerequisites
●
The valve has been removed, see
Tools
●
Lubricants Rivolta F.L.G. MD-2 and PARALIQ GTE
ATTENTION
Damage to seals and threads
Stainless steel threads tend to seize and stick, and must be greased. Damage to seals
and threads can result in malfunction.
●
Ensure that an adequate film of lubricant is applied. No grease residues must be
visible once the valve has been assembled completely.
●
For product contact seals only use suitable greases and oils.
●
Observe the safety data sheets issued by the lubricant manufacturer.
1.
Apply a light film of lubricant to all threads.
2.
Grease all seals – including the O-rings at the top and bottom of the actuator pis-
ton stem – very thinly.
®
Do not grease the V-ring.
3.
Grease the inside of the seal ring (1) (contact surface).
Þ
Seals and threads have been lubricated.
INFO
GEA Tuchenhagen recommends Rivolta F.L.G. MD-2 and PARALIQ GTE
703. These lubricants are approved for foodstuff and are resistant to
beer froth. They have the NSF-H1 (USDA H1) registration. They do not
affect the taste or the consistency of the products and are compatible
with the seals in contact with product. Rivolta F.L.G. MD-2 can be or-
dered from GEA Tuchenhagen. Using other types of grease can result
in malfunctions or in premature seal failure. The warranty will also be-
come null and void. A Manufacturer's Declaration for these products
can be obtained from GEA Tuchenhagen if required. A thin film of
grease is required on the seals to ensure the proper function of the fit-
tings. It reduces friction and extends the service life of the seals. This is
absolutely harmless from a health and hygienic point of view. Running
dry must be avoided!
104 / 128 - 9.7 Maintenance
0000000607 - 002 - EN-GB
Summary of Contents for ECOVENT
Page 6: ...6 128 Table of Contents 0000000607 002 EN GB...
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 128...
Page 12: ...12 128 1 4 Declarations of conformity 0000000607 002 EN GB...
Page 20: ...20 128 2 10 Emergency measures 0000000607 002 EN GB...
Page 40: ...40 128 5 5 Checking the pneumatic connection 0000000607 002 EN GB...
Page 44: ...44 128 7 3 Shutdown 0000000607 002 EN GB...
Page 106: ...106 128 9 7 Maintenance 0000000607 002 EN GB...
Page 120: ...120 128 12 2 Spare parts list 0000000607 002 EN GB...
Page 127: ...13 2 List of abbreviations 127 128...