Tool bit 6.3-PH2 Philips 89 mm
ATTENTION
The switch bar is sensitive and must be protected from impact stress.
Damage to switch bar.
●
Protect the switch bar against impact stress.
ATTENTION
Magnetic fields in the switch bar (1)
Magnetic fields can delete data carriers and affect or destroy electronic or mechani-
cal components.
●
Keep the switch bar away from data carriers and electronic and mechanical com-
ponents.
ATTENTION
Sensitive sealing surfaces in the actuator
The sealing surfaces on the cylinder can become damaged.
●
Take care no dirt enters the actuator.
1.
Push the O-ring (98) onto the lantern
(9).
2.
Place the locking ring (4) onto the lan-
tern (9)
3.
Screw the lantern (9) into the actuator
(140) and tighten with the open-end
plug tool ECO-Lat (Z). To do this, affix
with a belt wrench.
®
Observe torques, see table ‘Tight-
ening torques’.
9
A
4
Z
98
78 / 128 - 9.6 Installing the valve