5 Assembly and installation
This chapter contains information and instructions about the assembly and installation
of the valve.
It is addressed to all persons who carry out actions related to the valve.
INFO
During assembly and installation, observe chapter
ing Instructions.
5.1 Notes on installation
The valve can be installed in any position. Steps must be taken to ensure that the valve
housing and the pipe system can drain properly.
If the valve is installed in the horizontal position, pay attention that the vent hole in the
actuator is aligned horizontally on one side.
To avoid damage, ensure that the valve is installed into the pipe system without tension
and no objects remain in the system after assembly (e.g. tools, screws, lubrication oils).
If the valve is installed horizontally, the stress on the valve stem seals is higher than in
the vertical installation position. Therefore, support the actuator and regularly check
the valve for leakage.
5.2 Control top
If different valves are operated via a control top, it must be ensured for each of the
connected valves that the air supply does not fall below the required operating points.
5.3 Install the valve with detachable pipe connection
elements
Prerequisites
●
The pipe is drained, and cleaned or rinsed, if necessary.
●
The pipe section for the valve to be mounted must be separated from the re-
maining pipe system.
1.
Fit valves with detachable pipe connection elements – using suitable connection
fittings – directly into the pipe system.
Þ
Valve is installed.
5.4 Install valve with welding ends
WARNING
Spring tension in the valve (NC)
Danger of injury when opening the clamp connections on the actuator or on the
housing as the released spring pretension will suddenly lift the actuator.
●
Therefore, release the spring tension before detaching the clamp connection by
pressurising the actuator with compressed air at max. 8 bar.
5.1 Notes on installation - 35 / 128
Summary of Contents for ECOVENT
Page 6: ...6 128 Table of Contents 0000000607 002 EN GB...
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 128...
Page 12: ...12 128 1 4 Declarations of conformity 0000000607 002 EN GB...
Page 20: ...20 128 2 10 Emergency measures 0000000607 002 EN GB...
Page 40: ...40 128 5 5 Checking the pneumatic connection 0000000607 002 EN GB...
Page 44: ...44 128 7 3 Shutdown 0000000607 002 EN GB...
Page 106: ...106 128 9 7 Maintenance 0000000607 002 EN GB...
Page 120: ...120 128 12 2 Spare parts list 0000000607 002 EN GB...
Page 127: ...13 2 List of abbreviations 127 128...