2.
Pressurize the actuator - with com-
pressed air, max. 8 bar (air connection
61).
®
The valve disk is raised.
3.
Remove clamp connection (43) be-
tween the upper and middle housing.
4.
Depressurize the actuator (air connec-
tion 61).
®
The valve disk is lowered.
The valve insert is pushed out of
the housing.
35.1
61
43
Þ
The clamp connection between the upper and middle housing has been disman-
tled.
9.5 Removing the valve - 57 / 128