Never reach into the lantern (9) or the valve housing (391) when the valve is switch-
ing. Fingers can be crushed or cut off.
●
On a spring-closing valve there is danger of injury when the clamp connection (43) is
opened, as the released spring pretension will suddenly lift the actuator. Therefore,
release the spring tension before detaching the clamp connection (43) by supplying
the actuator (A) with compressed air.
●
The housing sockets (391) have very sharp edges. When transporting and installing
the valve be sure to wear suitable protective gloves.
●
On versions with proximity switch holder do not put your fingers in the slots (C).
Dangerous situations can be avoided by safety-conscious and proactive behaviour of
the personnel and by wearing personal protective equipment.
Danger
Cause
Measure
Danger to life
Inadvertent switch-on of the valve
Effectively disconnect all components,
effectively prevent switch-on.
Electric power
Observe the following safety rules:
1
.
Isolate from the power supply.
2
.
Take appropriate measures to pre-
vent switch on.
3
.
Test absence of voltage.
4
.
Earthing and short-circuiting.
5
.
Cover or safeguard any adjacent
live parts.
Spring tension in the actuator
Danger to life caused by the pressur-
ised spring in the actuator. Do not
open the actuator, rather return it to
GEA Tuchenhagen for proper disposal.
Risk of injury
Danger presented by moving or sharp-
edged parts
The operator must exercise caution
and prudence.
For all work:
●
Wear suitable work clothing.
●
Never operate the machine if the
cover panels are not correctly fit-
ted.
●
Never open the cover panels dur-
ing the operation.
●
Never reach into openings.
As a precautionary measure, wear per-
sonal protective equipment in the vi-
cinity of the valve:
●
Protective gloves
●
Safety shoes
Environmental dam-
age
Operating materials with properties
which are harmful to the environment
For all work:
●
Collect lubricants in suitable col-
lecting vessels.
●
Dispose of lubricants in accord-
ance with the pertinent regula-
tions.
18 / 128 - 2.8 Residual hazards
0000000607 - 002 - EN-GB
Summary of Contents for ECOVENT
Page 6: ...6 128 Table of Contents 0000000607 002 EN GB...
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 128...
Page 12: ...12 128 1 4 Declarations of conformity 0000000607 002 EN GB...
Page 20: ...20 128 2 10 Emergency measures 0000000607 002 EN GB...
Page 40: ...40 128 5 5 Checking the pneumatic connection 0000000607 002 EN GB...
Page 44: ...44 128 7 3 Shutdown 0000000607 002 EN GB...
Page 106: ...106 128 9 7 Maintenance 0000000607 002 EN GB...
Page 120: ...120 128 12 2 Spare parts list 0000000607 002 EN GB...
Page 127: ...13 2 List of abbreviations 127 128...