Spring-to-open valve (NO) with control head T.VIS
INFO
Removal step: remove the clamp connection between the upper and mid-
dle housing
Tools
●
Jaw wrench, a/f 12/13
●
Jaw wrench, a/f 13/17
●
Articulated face spanner with journal 4 mm
●
Hex key, a/f 3
ATTENTION
The switch bar is sensitive and must be protected from impact stress.
Damage to switch bar.
●
Protect the switch bar against impact stress.
ATTENTION
Magnetic fields in the switch bar (1)
Magnetic fields can delete data carriers and affect or destroy electronic or mechani-
cal components.
●
Keep the switch bar away from data carriers and electronic and mechanical com-
ponents.
1.
Remove the clamp connection (43) between the upper and middle housing.
®
Observe torques, see
.
92 / 128 - 9.6 Installing the valve
0000000607 - 002 - EN-GB