9.5.4 Dismantling of the housing combination
Prerequisites
●
This housing combination does not exist for welded housings
Tools
●
Jaw wrench, a/f 10/11
●
Jaw wrench, a/f 12/13
●
Jaw wrench a/f24
1.
Remove the blanking plate (35):
1.1
Remove the clamp connection
(43) on the housing in the pipe.
1.2
Remove the blanking plate (35).
5
43
35
33
5
5
2.
Take the seat ring (33) out of the housing in the pipe
Þ
Housing combination is disassembled.
All seals are freely accessible.
9.6 Installing the valve
9.6.1 Tightening torques
Tighten the following valve connections to the torques specified in the table.
Tightening torques
[Nm]
[lbft]
Valve disk
M14
45
33
Lantern
M34
60
44.2
Mounting base
M34
60
44.2
Blanking plate ECO-E
M34
5
3.7
INI holder
M34
Switch bar
M14
2-2.5
1.5-1.8