5.
For optional version with proximity
switch holder (C):
5.1
Screw the mounting for the
proximity switch (C) into the ac-
tuator using the jaw wrench on
the wrench flat surface (C3).
5.2
Screw the switch bar (139) into
the mounting for proximity
switch (C) on the wrench flat
surface (139.1) using a jaw
wrench (a/f 17).
®
Observe torques, see table ‘Tighten-
ing torques’.
.
C2
C
C1
139
139.1
C3
6.
Press the bearing (2) into the lantern
(9).
7.
Place the seal disk (3) with the O-ring
(5) and seal ring (1) into the housing.
8.
Place the lantern (9) onto the housing
and mount the hinged clamp (43) be-
tween the housing and the lantern.
®
Observe torques, see table ‘Tight-
ening torques’.
.
9.
Place the seat ring (33) with the O-
ring (5) into the housing.
10.
Screw valve disk (15) with the V-ring
(7) into actuator and tighten using
jaw wrench at wrench flat surface
(15.1). To do this, affix with a belt
wrench.
®
Observe torques, see table ‘Tight-
ening torques’.
.
9
2
3
43
1
5
15
7
7
33
5
5
15.1
Þ
The valve insert is assembled from individual parts.
9.6 Installing the valve - 81 / 128
Summary of Contents for ECOVENT
Page 6: ...6 128 Table of Contents 0000000607 002 EN GB...
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 128...
Page 12: ...12 128 1 4 Declarations of conformity 0000000607 002 EN GB...
Page 20: ...20 128 2 10 Emergency measures 0000000607 002 EN GB...
Page 40: ...40 128 5 5 Checking the pneumatic connection 0000000607 002 EN GB...
Page 44: ...44 128 7 3 Shutdown 0000000607 002 EN GB...
Page 106: ...106 128 9 7 Maintenance 0000000607 002 EN GB...
Page 120: ...120 128 12 2 Spare parts list 0000000607 002 EN GB...
Page 127: ...13 2 List of abbreviations 127 128...