4.
Equip the installation base (198.2)
with O-rings (98, 99) and slide bear-
ings (202) and position in the installa-
tion base (198.1).
5.
Screw the installation base unit into
the actuator using the articulated face
spanner, and tighten.
®
Observe torques, see table ‘Tight-
ening torques’.
.
99
198.1
98
202
198.2
6.
Press the bearing (2) into the lantern
(9).
7.
Place the seal disk (3) with the O-ring
(5) and seal ring (1) into the housing.
8.
Place the lantern (9) onto the housing
and mount the hinged clamp (43) be-
tween the housing and the lantern.
®
Observe torques, see table ‘Tight-
ening torques’.
.
9.
Place the seat ring (33) with the O-
ring (5) into the housing.
10.
Screw valve disk (15) with the V-ring
(7) into actuator and tighten using
jaw wrench at wrench flat surface
(15.1). To do this, affix with a belt
wrench.
®
Observe torques, see table ‘Tight-
ening torques’.
.
1
9
2
1
3
5
43
33
5
5
15
15.1
7
7
11.
Screw the switch bar (1) into the actuator using a jaw wrench.
Þ
The valve insert is assembled from individual parts.
9.6 Installing the valve - 79 / 128
Summary of Contents for ECOVENT
Page 6: ...6 128 Table of Contents 0000000607 002 EN GB...
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 128...
Page 12: ...12 128 1 4 Declarations of conformity 0000000607 002 EN GB...
Page 20: ...20 128 2 10 Emergency measures 0000000607 002 EN GB...
Page 40: ...40 128 5 5 Checking the pneumatic connection 0000000607 002 EN GB...
Page 44: ...44 128 7 3 Shutdown 0000000607 002 EN GB...
Page 106: ...106 128 9 7 Maintenance 0000000607 002 EN GB...
Page 120: ...120 128 12 2 Spare parts list 0000000607 002 EN GB...
Page 127: ...13 2 List of abbreviations 127 128...