Dimensions sheet - shuttle valve
221MBL002591EN_1
01.06.2023
2
With control head T.VIS
Dimension
DN 25
DN 40
DN 50
DN 65
DN 80
DN 100
A
50
62
74
96
111
130
C
90
90
90
125
125
125
C1
31
39
41
52
59
70
Ø
26
38
50
66
81
100
Stroke
15
24
24
26
26
26
K
V
value
I - II m
3
/h
26.331
60.023
119.735
202.425
261.351
519.257
I - III m
3
/h
24.308
23.887
37.527
63.914
116.910
143.209
III - I m
3
/h
24.688
38.557
56.596
101.623
109.198
184.279
III - V m
3
/h
17.841
39.886
72.702
110.610
137.544
247.344
V - III m
3
/h
17.952
44.383
66.080
124.165
136.012
219.919
Actuator
E_AA
E_BB
E_BB
E_CD
E_CD
E_DF
D
85
104
104
129
129
169
F
169
203
209
217
224
234
H
338
372
378
386
393
402
X
385
431
449
480
508
537
With control head T.VIS
Dimension
1" OD
1.5" OD
2" OD
2.5" OD
3" OD
4" OD
A
46
59
71.5
90
103
127.5
C
90
90
90
125
125
125
C1
29
39
42
54
53
69
Ø
22
35
47.5
60
73
97.5
Stroke
11
24
24
26
26
26
K
V
value
I - II m
3
/h
14.791
44.443
96.328
169.777
264.872
541.518
I - III m
3
/h
9.369
23.684
28.421
55.436
68.215
137.412
III - I m
3
/h
10.876
30.106
45.141
84.536
93.086
178.421
III - V m
3
/h
11.434
34.441
57.098
90.937
114.020
234.275
V - III m
3
/h
12.602
38.691
57.938
118.189
116.269
207.512
Actuator
E_AA
E_BB
E_BB
E_CD
E_CD
E_DF
D
85
104
104
129
129
169
F
167
201
208
214
220
233
H
364
370
377
383
389
402
X
407
427
446
471
491
534
122 / 128 - 13.1 Dimension sheets
0000000607 - 002 - EN-GB
Summary of Contents for ECOVENT
Page 6: ...6 128 Table of Contents 0000000607 002 EN GB...
Page 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 128...
Page 12: ...12 128 1 4 Declarations of conformity 0000000607 002 EN GB...
Page 20: ...20 128 2 10 Emergency measures 0000000607 002 EN GB...
Page 40: ...40 128 5 5 Checking the pneumatic connection 0000000607 002 EN GB...
Page 44: ...44 128 7 3 Shutdown 0000000607 002 EN GB...
Page 106: ...106 128 9 7 Maintenance 0000000607 002 EN GB...
Page 120: ...120 128 12 2 Spare parts list 0000000607 002 EN GB...
Page 127: ...13 2 List of abbreviations 127 128...