Tightening torques
[Nm]
[lbft]
Clamps on the control top
1
0.7
Cap
1
0.7
Clamp connection
M6
9
6.6
M8
22
16.2
M10
45
33
9.6.2 Assembling the valve insert from individual parts
Mounting the clamp connection depends on how the valve is configured:
●
Spring-to-close valve (NC) with control head T.VIS
●
Spring-to-close valve (NC) without control head T.VIS
●
WARNING
Risk of injury when mounting sharp-edged parts
●
Do not put your hand into the valve housing.
ATTENTION
Sensitive valve parts
Damage to the valve parts can lead to a malfunction.
●
Protect the valve parts against impact stress.