4.2 KEYPAD INTERFACE
4 USER INTERFACE
4
4.2.5 VIEWING & CHANGING STATUS MODE PARAMETERS
To view or change the SPM status information, the user must enter the STAT MODE. This can be accom-
plished with the motor either off or in running mode. Use the following procedure to enter the STAT MODE:
1.
With the display indicating the following, press the GE key (items in bold italics indicate that they should be
blinking on the screen):
2.
The display should now indicate that the unit is in STAT MODE:
3.
Use the
/
keys to scroll through the STAT MODE parameters.
4.
If the SPM is configured such that status mode parameters are "read only", then these values can only be
viewed and cannot be changed. If the SPM is configured such that status mode parameters are "read/
write", then these values can be changed as follows.
5.
Once the parameter that is to be changed is displayed on the display, press
to select the parameter:
6.
Use the
/
keys to change the values of the selected parameter and then press the
key to con-
tinue. If you choose not to change the parameter once it has been selected, pressing the GE key deselects
the parameter.
7.
Additional parameters can be changed using the above procedure. When all parameter changes have
been accomplished, press the GE Key. This will return the display to the STAT MODE main menu. Press
the GE key again and the display will change to the PROGRAMMING MODE main menu. Pressing the GE
key again puts the display into the TEST MODE main menu. Pressing the GE key gain will then return the
display to the SPM READY display.
4.2.6 ALTERNATE MENU OPERATION
In order to view setpoints without changing values, or to view setpoints if the password is unknown, the alter-
nate menu can be used. When the SPM is in the ready mode,
press the
key and the SPM will automatically switch into the alternate menu. The SPM will begin to auto-
matically scroll through the setpoints. Pressing either of the
/
keys once will halt the display. Pressing
either of the
/
keys repeatedly will allow the user to scroll through the setpoints manually. This allows
the user to scroll through the setpoints using the
/
keys but does not allow setpoints to be changed. To
return to the SPM READY display, press the
key.
Collr-Ring Motor
SPM READY
STAT MODE
SCROLL for menus
MOTOR HRS: 0
SELECT to modify
MOTOR HRS:
0
SCROLL to change
Collr-Ring Motor
SPM READY
ENTER
ENTER
ENTER
ENTER
Summary of Contents for SPM Series
Page 2: ......
Page 4: ......
Page 10: ...vi SPM Synchronous Motor Protection Control GE Power Management TABLE OF CONTENTS...
Page 74: ...6 4 SPM Synchronous Motor Protection Control GE Power Management 6 2 STATUS 6 ACTUAL VALUES 6...
Page 120: ...C 2 SPM Synchronous Motor Protection Control GE Power Management C 1 WARRANTY APPENDIXC C...
Page 124: ...iv SPM Synchronous Motor Protection Control GE Power Management INDEX...
Page 125: ...GE Power Management SPM Synchronous Motor Protection Control NOTES...