![GE Multilin 489 Instruction Manual Download Page 174](http://html.mh-extra.com/html/ge/multilin-489/multilin-489_instruction-manual_123013174.webp)
5–64
489 GENERATOR MANAGEMENT RELAY – INSTRUCTION MANUAL
CHAPTER 5: SETPOINTS
5.9
S8 RTD Temperature
5.9.1
RTD Types
PATH: SETPOINTS
ZV
S8 RTD TEMPERATURE
Z
RTD TYPES
Each of the twelve RTDs may be configured as None or any one of four application types,
Stator, Bearing, Ambient, or Other. Each of those types may in turn be any one of four
different RTD types: 100 ohm Platinum, 120 ohm Nickel, 100 ohm Nickel, 10 ohm Copper.
The table below lists RTD resistance vs. temperature.
1 RTD TYPES
[
Z
]
STATOR RTD TYPE:
100 Ohm Platinum
Range: 100 Ohm Platinum, 120 Ohm
Nickel, 100 Ohm Nickel, 10 Ohm
Copper
MESSAGE
BEARING RTD TYPE:
100 Ohm Platinum
Range: as above
MESSAGE
AMBIENT RTD TYPE:
100 Ohm Platinum
Range: as above
MESSAGE
OTHER RTD TYPE:
100 Ohm Platinum
Range: as above
Table 5–6: RTD Temperature vs. Resistance
Temperature
100
Ω
Pt
(DIN 43760)
120
Ω
Ni
100
Ω
Ni
10
Ω
Cu
° C
° F
–50
–58
80.31
86.17
71.81
7.10
–40
–40
84.27
92.76
77.30
7.49
–30
–22
88.22
99.41
82.84
7.88
–20
–4
92.16
106.15
88.45
8.26
–10
14
96.09
113.00
94.17
8.65
0
32
100.00
120.00
100.00
9.04
10
50
103.90
127.17
105.97
9.42
20
68
107.79
134.52
112.10
9.81
30
86
111.67
142.06
118.38
10.19
40
104
115.54
149.79
124.82
10.58
50
122
119.39
157.74
131.45
10.97
60
140
123.24
165.90
138.25
11.35
70
158
127.07
174.25
145.20
11.74
80
176
130.89
182.84
152.37
12.12
90
194
134.70
191.64
159.70
12.51
100
212
138.50
200.64
167.20
12.90
110
230
142.29
209.85
174.87
13.28
120
248
146.06
219.29
182.75
13.67
130
266
149.82
228.96
190.80
14.06
140
284
153.58
238.85
199.04
14.44
150
302
157.32
248.95
207.45
14.83
160
320
161.04
259.30
216.08
15.22
170
338
164.76
269.91
224.92
15.61