8.2.4 Lubrication and Cleaning of X Liner Rail
1. Take out the Grease Syringe from accessory box
2. Remove the lubrication slot plate on the X rails
3. Inject 0.1ml of grease to the injection opening inside the linear bearing, and move the lens
carriage to smooth the grease and movement
4. Repeat the step 3 till the grease is full out of the linear bearing
5.
Repeat the step 3 and 4 to the injection opening in opposite side of the linear bearing
6.
Seal the lubrication slot plate back to the X rail
Inject 0.1ml of grease to this
injection opening inside the linear
bearing