Page 6-4
G1000/GFC 700 Post Installation Checkout Procedure - Hawker / Beechcraft King Air C90
Revision 5
190-00682-00
Step Desired
Result
PFD1 Display Failure Conditions:
1. Open PFD 1 PRI and PFD1 SEC circuit
breakers.
2. Verify desired results.
The following shall occur when power is removed
from PFD1:
•
PFD1 goes blank.
•
PFD2 and MFD remain in normal display formats.
The following illuminate on PFD2:
•
GMA1 Fail – GMA1 is inoperative.
•
XPDR1 Fail – XPDR1 is Inoperative.
•
XTALK ERROR – A flight display crosstalk error
has occurred.
PFD1 and MFD Display Failure Conditions:
1. Open MFD circuit breaker.
2. Verify desired results.
3. Close MFD, PFD 1 PRI and PFD1 SEC
circuit breakers.
The following shall occur when power is removed
from PFD1 and MFD:
•
MFD goes blank.
•
The following illuminate on PFD2:
−
HDG NO COMP illuminates on PFD2
−
ROLL NO COMP illuminates on PFD2
−
PIT NO COMP illuminates on PFD2
−
IAS NO COMP illuminates on PFD2
−
ALT NO COMP illuminates on PFD2