Page 2-16
G1000/GFC 700 Post Installation Checkout Procedure - Hawker / Beechcraft King Air C90
Revision 5
190-00682-00
2.10
FliteCharts Configuration
Follow this procedure to re-enable FliteChart function if ChartView has been enabled for the G1000
system.
FliteCharts is a default G1000 system function. If ChartView has not been enabled, the following
procedure is not required. If ChartView has previously been enabled, perform the procedure below to
return FliteCharts function to the G1000 system if required.
This procedure will re-load the C90 baseline configuration. Any options previously enabled such as DME,
ADF etc will need to be re-enabled per the instruction contained in this document.
NOTE
The G1000 can only be configured for FliteCharts or ChartView but not both. Performing this procedure
will automatically disable the ChartView function. Coordinate this configuration with section 3.17
“FliteChart Functional Checks”.
1. Ensure the appropriate loader card is inserted in the top card slot of PFD1
2. With PFD1 in configuration mode, select the “
System Upload
” page using PFD1 small FMS knob.
3. Activate the cursor and use the small FMS knob to highlight “
C90
” in the AIRFRAME field. Press the
ENT
key to select the airframe type.
Ensure that the correct airframe type is selected before proceeding; otherwise, incorrect configuration
information will be loaded.
4. Once an airframe type is selected the cursor moves to the FILE window. Rotate the small FMS knob
to activate the drop-down menu. Move the cursor to highlight “
King Air C90 Baseline
” and press
ENT
.
Note: The PRODUCT window displays information regarding each G1000 LRU. The LRU column
depicts the reported software version of the LRU, whereas the CARD VERS column shows the LRU
software version stored on the Loader Card. The SOFTWARE and CONFIGURATION columns
default to having all required boxes checked. Each checked file is automatically loaded to the correct
G1000 LRU.
5. Press
the
LOAD
softkey.
6. Observe software loading progress and verify software load completes without errors as indicated by
the following:
a. Green “PASS” or N/A in the Configuration column.
b. “Upload Complete………….COMPLETE” in the summary box.
7. Press
ENT
to acknowledge the “Upload Complete” box.
8. Reload other C90 options as appropriate per instructions contained within this document.
IMPORTANT