Page 2-12
G1000/GFC 700 Post Installation Checkout Procedure - Hawker / Beechcraft King Air C90
Revision 5
190-00682-00
2.7
StormScope (WX-500) Option Configuration
2.7.1
Stormscope (WX-500) Option
1. With PFD1 configuration mode and loader card inserted in the top card slot of PFD1, select the
“
System Upload
” page using the PFD1 small FMS knob.
2. Activate cursor and rotate inner knob to display drop down menu. Highlight “
C90-Options
” and press
PFD1
ENT
key
.
3. Verify cursor drops down to the file box. Rotate the inner FMS knob to view the list of available C90
Options.
4. Use the FMS inner knob to select “
King Air C90 – WX 500 Option
”. Press
ENT
.
5. Verify the “
King Air C90 – WX 500 Option
” configuration file is displayed in the “File” window. Press
“
LOAD
”.
6. Monitor load progress. Verify software load completes without errors as indicated by the following:
7. Green “PASS” in Configuration column.
8. “Upload Complete………….COMPLETE” in the summary box.
9. Select
PFD1
ENT
key to acknowledge upload complete.
10. Deactivate cursor.