G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air
Page 5-63
190-00716-01
Revision 1
5.12 GEA
Troubleshooting
5.12.1
GEA Alerts
Failure Message
Cause
Solution
MANIFEST – GEA1 software
mismatch. Communication
halted.
The system has detected an
incorrect software version loaded
in the specified GEA 71.
Load the correct software verion. See
Section 3.9 for GEA 71 Software Load
Procedure.
MANIFEST – GEA2 software
mismatch. Communication
halted.
GEA1 CONFIG – GEA1
configuration error. Config service
req’d.
The system has detected a
configuration mismatch in the
specified GEA 71.
•
Load GEA configuration files. See
Section 3.9 for GEA 71
Configuration Procedure.
•
If problem persists, replace master
configuration module, check config
module harness for faults and
replace if necessary.
NOTE
New Terrain/Obstacle cards,
Jeppesen Aviation Database and
other optional features (i.e. TAWS
unlock card) will need to be
replaced if the master configuration
module is changed. The G1000
System ID number will change to a
new number when installing a new
master config module. The old
Terrain and other cards will no
longer work as they will remain
locked to the old System ID
number.
GEA1 CONFIG – GEA2
configuration error. Config service
req’d.
Summary of Contents for Cessna Caravan G1000
Page 2: ...This page intentionally left blank...
Page 89: ......