OPERATION
DETAILED CONTROLS AND GAUGES
3-31
Swing Holding Brake Release Switch
NOTICE
This switch makes it possible to carry out swing operations
for a short time even when there is an abnormality in the
swing brake system. Do not use this switch except in emer-
gencies. Repair the abnormality as soon as possible.
This switch (11) is used to make it possible to carry out operations
temporarily if any abnormality should occur in the swing brake
system (when the display shows E03).
(a) Release: Position for abnormality (switch moved up)
(b) Normal: Normal position (switch moved down)
q
When the display is "E03", move this switch up to make it possible to carry out operations.
q
When the switch is set to the Release (a) position, the swing lock monitor flashes.
Revolving Warning Lamp Switch
(If equipped)
This switch (12) is used to light up the yellow rotating lamp on top
of the cab.
(a) ON: Lamps light up
(b) OFF: Lamps go off