MAINTENANCE SCHEDULE
MAINTENANCE
4-18
MAINTENANCE INTERVAL FOR HYDRAULIC BREAKER
4
For machine equipped with a hydraulic breaker, the hydraulic oil deteriorates faster than for normal bucket digging
operations, so set the maintenance intervals as follows.
REPLACE HYDRAULIC OIL FILTER ELEMENT
q
On new machines, replace the element after the first 100 to
150 hours, then carry out further replacement of the element
according to the table on the right.
CHANGE OIL IN HYDRAULIC TANK
q
Change the oil according to the table on the right.
REPLACE ADDITIONAL FILTER ELEMENT FOR BREAKER
q
Use a guideline of 250 hours for use of the breaker (operating ratio for the breaker: 50 % or more), and replace
the element according to the table on the right.