635/600-SERIES HARDWARE INSTALL GUIDE
Chapter-Page
1-5
Power Supply (LifeSafety FPO75) for Controller (no transformer needed / for US or International):
The LifeSafety FPO75 (75 Watt) Power Supply does not use a plug-in transformer. LifeSafety Power Supply is
compatible for international installations.
CAUTION
:
Power Input Jumper (JP1) is set 120 VAC/ 60 HZ
(Factory Default; i.e. JP1 is closed/not cut)
.
You must correctly configure the power input JP1 jumper wire – see FlexPower install manual that is shipped
with the power supply. Failure to correctly configure JP1 will cause equipment damage or hazard.
•
For 120 VAC / 60 Hz input power = JP1 CLOSED (Factory Default)
Do not cut JP1 Jumper Wire.
•
For 230 VAC / 50 Hz input power = JP1 OPEN
Cut the JP1 Jumper Wire (at red dot).
•
Only use 12VDC Output switch position SW1. Galaxy Controllers do not support 24VDC.
1)
JP1
-
AC Input Voltage Jumper
(120/230VAC):
For 120VAC = JP1 is UNCUT (Factory Default)
For 230 VAC = JP1 Wire must be CUT
2)
J9
- AC Input Connector (3-prong)
3)
LED
- AC Power LED (ON/OFF)
4)
JP2
- Earth-Ground Jumper (enable/disable) =
DISABLED (position 2)
5)
JP3
- Battery Jumper (enable/disable) =
ENABLED (position 1)
6)
J2/J3
- Battery Connections for back up battery (+/-)
7)
TB1
- Terminal Block for DC Voltage Output Lugs (DC1)
8)
LED
- DC Power LED (
ON/OFF
)
9)
J1
(or SW1)
-
DC Output Voltage Jumper
=
must be set to the
12V position!
Also:
SYSTEM FLT LED - Can indicate a missing battery when JP3 is “enabled” and AC power is applied/on.