635-SERIES HARDWARE M ANUAL
Chapter-Page
2-56
4.
The Config Tool automatically detects all 635 CPU’s by MAC address on the same network segment
if the
CPU’s
web enable
option is ON (factory default) AND the cabinet door is open (tamper switch). You must use
Putty or HyperTerminal if the web-enable option is turned off.
a)
Click the Serial Number
of the panel to Configure Network parameters of the CPU.
~OR~
b)
Click the IP Address
to view Panel Status screen and configure daughter boards.
•
View current programming, set Panel’s Date/Time, see list of daughter boards.
•
Click the
Configure Panel link
to
configure the Panel’s Cluster and Unit IDs and program the Event
Server connection settings.
•
Click the
board’s Serial#
to
configure or test the daughter boards.
Figure 44 – Example of ‘All Panel Summary’ screen – LIST OF DETECTED PANELS
The All Panel Summary (home) page opens in your default browser.
635 Panels must be powered up, connected to the same broadcast domain, and the
CABINET DOOR on the Panel
MUST BE OPEN (TAMPER SWITCH ACTIVE)
.