Logging
The FileWeb interface allows the MC to transfer its files to a web site for download which can then be viewed
using a standard web browser. This interface provides the user the ability to setup a web site to store files for
local or global access without installing an FTP server. The MC supports https:// (secure) transfer of files.
MC Field Setup
FileWeb Server Setup
Type = FileWeb
FileWeb server setup (see Appendix section A.2 FTP, FileWeb,
DataWeb Requirements/Installation for additional information).
IP Add = https://fdctuil.com/xxxx.svc
Actual named address of FileWeb server/service.
User = userName
Actual user name for login at FileWeb server (required).
Password = userPassword
Actual password for login at FileWeb server (required).
Server = myFileWeb
FileWeb server setup with a root directory named “myFileWeb”.
The FileWeb server directory path must exist and match the MC
setup for proper operation. If there is an additional directory
within the “myFileWeb” root directory, its name would be
appended to the path. (i.e. myFileWeb/Files if a “Files” directory
inside the myFileWeb server root directory is the target for
transfer).
Port = 21
Port used at MC and open at FileWeb server.
NOTE:
Make sure proper permissions are set at the FileWeb server for access/creation of directories and
read/write access. Also check root directory structure at Server to identify the actual root that was
created for the files since there can be additional layers created by the server and displayed in the path.
The DataWeb interface allows the MC to transfer data to a web data base service using MySQL and Microsoft
IIS as a web platform. The MC can interface directly to a local or Web data base (Cloud) thereby allowing
access to any system globally without any special “client” applications required to view the data. This allows
the MC to share data with local or global manufacturing systems by storing data directly to a manufacturing
database. The MC supports https:// (secure) transfer of data.
MC Field Setup
DataWeb Server Setup
Type = DataWeb
FileWeb server setup (see Appendix section A.2 FTP,
FileWeb, DataWeb Requirements/Installation for additional
information).
IP Add = https://fdctuil.com/xxxx.svc
Actual named address of DataWeb server/service.
User = userName
Actual user name for login at FileWeb server (required). This
is the directory where the database structure will reside on
the server. The MC will use this directory path for sending
data to the database.
Password = userPassword
Actual password for login at DataWeb server (required).
Server = not used
The directory where the database exists uses the userName
as the default location for data storage.
Port = 21
Port used at MC and open at DataWeb server.
NOTE:
An IT professional with experience is required for DataWeb server setup. Future Design Controls does
not support server side programming or setup but can offer 3
rd
party resources to assist with or handle
complete server side projects.
Summary of Contents for MCT-MC 4.3
Page 1: ...MCT MC 4 3 User Manual MCT MC 4 3 User Manual Rev A February 2018...
Page 176: ...MCT MC4 3 FDC MCT MC 176 Appendix...
Page 177: ...MCT MC4 3 Appendix 177 FDC MCT MC Open Frame Power Supply Specifications...
Page 178: ...MCT MC4 3 FDC MCT MC 178 Appendix...
Page 179: ...MCT MC4 3 Appendix 179 FDC MCT MC A 6 Power On Delay Relay Specifications GE1A C10HA110...
Page 180: ...MCT MC4 3 FDC MCT MC 180 Appendix...