MCT-MC
4.3
Offline Setup
- 135 -
FDC MCT-MC
Proceed to the Expert tab. Scroll down the list of settings until you find the “PreferredEncoding” and
“Protocol3.3” options. Set the preferred encoding to Hextile and the Protocol 3.3 option to true. Verify that the
“Use these settings for all new connections” checkbox at the bottom of the window is checked and click the OK
button. This will set the selections to the default start settings for the VNC viewer.
11.1.4.2 Recommended VNC Viewer Settings for Tablets
The VNC clients for tablets have been found to offer limited flexibility for use with the MC. Most clients have
default settings requiring security to be enabled on the server in order to connect. If you have trouble connecting
with a VNC viewer through an iPad, iPhone or even an Android based phone, start by enabling the security on
the MC VNC server and be sure to enter those settings in the client viewer.
Color and encoding options can also affect the connectivity. If the client offers the option, leave color and
encoding options to “automatically detect” or “server decides”. If the client is still unable to connect, try default
encoding of Hextile and set the color option to limited colors such as 256 bit color. Future Design Controls does
not write or create VNC clients (3rd party software), so final selection of client and testing is the end user
responsibility. The following settings are provided as an example for the Remotix client for the iPad. When
adding an MC server to the Remotix client, use the following settings. Note that the VNC server in the MC must
have security enabled in order for this client to connect.
Connection Type:
VNC
Host/IP:
IP address of MC
Port:
VNC address of MC (5900 = 0, 5901 = 1, etc…)
Use SSH Tunnel:
Off
VNC Authentication: VNC Password
VNC Password:
VNC password of MC
VNC Server Type:
AutoDetect
Operating System:
Windows
Preferred Encodings: Hextile
Color Depth:
16 bits
Summary of Contents for MCT-MC 4.3
Page 1: ...MCT MC 4 3 User Manual MCT MC 4 3 User Manual Rev A February 2018...
Page 176: ...MCT MC4 3 FDC MCT MC 176 Appendix...
Page 177: ...MCT MC4 3 Appendix 177 FDC MCT MC Open Frame Power Supply Specifications...
Page 178: ...MCT MC4 3 FDC MCT MC 178 Appendix...
Page 179: ...MCT MC4 3 Appendix 179 FDC MCT MC A 6 Power On Delay Relay Specifications GE1A C10HA110...
Page 180: ...MCT MC4 3 FDC MCT MC 180 Appendix...