XG1200 User's Guide
238/258
All Rights Reserved, Copyright (C) PFU LIMITED 2005
Message
IDSeverity
Message/Explanation/Solution
S7410
WARNING
Could not save a system-dump file.
Explanation
An error has occurred while storing system dump.
Solution
Note the message contents and contact your XG1200 sales representative.
S7411
ERROR
Could not execute system-dump.
Explanation
An error has occurred while storing system dump.
Solution
Note the message contents and contact your XG1200 sales representative.
S7490
CRITICAL
A system-dump has been saved. Cause: critical system error occurred.
Explanation
An error has occurred while storing system dump.
Solution
"Obtain maintenance information using the "
tftp put-maintanace
" command and then take a note of the message
content before contacting the XG1200 sales representative.
S7491
CRITICAL
A system-dump has been saved. Cause: dump switch was pressed.
Explanation
As the Dump switch was pressed, the system dump was saved.
Solution
"Obtain maintenance information using the "
tftp put-maintanace
" command and then take a note of the message
content before contacting the XG1200 sales representative.
S7492
CRITICAL
A system-dump has been saved. Cause: machine check occurred (memory or bus data error).
Explanation
An XG1200 machine check error has occurred and a system dump saved.
Solution
"Obtain maintenance information using the "
tftp put-maintanace
" command and then take a note of the
message content before contacting the XG1200 sales representative.
S7493
CRITICAL
A system-dump has been saved. Cause: machine check occurred (bus timeout).
Explanation
An XG1200 machine check error has occurred and a system dump saved.
Solution
"Obtain maintenance information using the "
tftp put-maintanace
" command and then take a note of the
message content before contacting the XG1200 sales representative.
S7494
CRITICAL
A system-dump has been saved. Cause: machine check occurred (memory or bus data error,
bus timeout).
Explanation
An XG1200 machine check error has occurred and a system dump saved.
Solution
"Obtain maintenance information using the "
tftp put-maintanace
" command and then take a note of the
message content before contacting the XG1200 sales representative.
S7495
CRITICAL
A system-dump has been saved. Cause: machine check occurred.
Explanation
An XG1200 machine check error has occurred and a system dump saved.
Solution
"Obtain maintenance information using the "
tftp put-maintanace
" command and then take a note of the
message content before contacting the XG1200 sales representative.
A.2.10
update (Firmware Update: 7500-7999)
Message
IDSeverity
Message/Explanation/Solution
S7500
INFO
init-firmup: New firmware '%1$' is running.
Explanation
New updated firmware was run.
[[Inserted string]]%1$: Firmware version information