XG1200 User's Guide
224/258
All Rights Reserved, Copyright (C) PFU LIMITED 2005
A.2
List of Event Logs
This section provides message contents, explanation and actions to take that are associated with message ID and severity in
ascending numerial order. The solution is not provided for messages for which you do not take action.
A.2.1 env (Supervisory Control: 0
-
999)
Message ID
Severity
Message/Explanation/Solution
S0101
ERROR
%1$ Temperature is out of range. (%2$)
Explanation
A temperature error has been detected.
[[Inserted string]]%1$: Location at which a temperature error was detected.
Inlet: The temperature near the inlet
Internal: The temperature inside the chassis
[[Inserted string]]%2$: Temperature value
Solution
Perform the following concerning the set up of XG1200:
Check that the air vent is not blocked.
Check that the temperature of the set up location is within the limits set out by the operation guarantee.
If the message is displayed even though the XG1200 has been properly installed, note the message contents
and contact your XG1200 sales representative.
S0102
WARNING
PWR-%1$ ALARM is detected.
Explanation
A power supply error has been detected.
[[Inserted string]]%1$: Power supply unit number
Solution
Replace the power supply unit.
S0103
WARNING
PWR-%1$ Hot Temperature.
Explanation
A temperature error has been detected in the power supply unit.
[[Inserted string]]%1$: Power supply unit number
Solution
Replace the power supply unit.
S0104
WARNING
PWR-%1$ is Off Line.
Explanation
It has been detected that no power is reaching the power supply unit.
[[Inserted string]]%1$: Power supply unit number
Solution
Check for AC inputs.
P0105
INFO
PWR-%1$ is On Line.
Explanation
Power has returned to power supply unit.
[[Inserted string]]%1$: Power supply unit number
P0106
INFO
PWR-%1$ is Removed.
Explanation
It has been detected that power supply unit has been removed.
[[Inserted string]]%1$: Power supply unit number
Solution
If a message is received during times other than hot swapping, check the installation status.
P0107
INFO
PWR-%1$ is Inserted.
Explanation
It has been detected that power supply unit was installed.
[[Inserted string]]%1$: Power supply unit number
Solution
If a message is received during times other than hot swapping, check the installation status.