XG1200 User's Guide
198/258
All Rights Reserved, Copyright (C) PFU LIMITED 2005
5.18.2 show log
Function
Displays system logs.
Prompt
xg#
Command syntax
show log { info | warning | error | critical } [ latest <1-10000> ]
Parameter
{ info | warning | error | critical }
Specifies a type of system log to be displayed.
−
info
Displays the INFO log.
The INFO log stores information (INFO) messages which report the system status of the XG1200.
−
warning
Displays the WARNING log.
The WARNING log stores the warning (WARNING) messages of the XG1200.
−
error
Displays the ERROR log.
The ERROR log stores the error (ERROR) messages of the XG1200.
−
critical
Displays the CRITICAL log.
The CRITICAL log stores the critical (CRITICAL) messages of the XG1200.
latest <1-10000>
Specifies the number of the latest log entries to be displayed within the range of 1 to 10000.
If omitted, all logs are displayed.
Command type
Operation management command
Output format
xg# show log info latest 1
May 25 22:08:33 xghost xgsh: XG INFO[P4001]: cmd-exec[3388]: show log info
| | | | | | | |
Month Day
Hours Min Sec
|
Function name
Severity
|
Message text
The XG1200's MessageID
Host name
Month
Displays the month when the event occurred.
Day
Displays the day when the event occurred.
Hours Min Sec
Displays the time (hours, minutes and seconds) when the event occurred.
Host name of the XG1200
Displays the time (hours, minutes and seconds) when the event occurred.
Function name
Displays the function name.
Severity
Indicates an importance level (or severity) of the message.
−
CRITICAL
Critical level.
The system has failed to continue its operation. Follow the instructions given by the message.
−
ERROR
Error level.
Part of system functions has failed although the system can continue its operations. Follow the instructions
given by the message.
−
WARNING
Warning level.
There is no problem in system operations although an error or a warning event has been detected. Check the
message information and determine the actions necessary to take.
−
INFO
Informational level.
This is an informational message showing the system status. No response is necessary.
MessageID
Displays the message ID in the “S message number” or “P message number” format.
−
S
Indicates that the message is notified with the SNMP trap.
−
P
Indicates that the message is not notified with the SNMP trap.
−
Message number
Displays a unique number for message identification. Read this message number to locate the message and
take the necessary actions.
Message text