Split system (Single phase and 3-phase type)
8
Maintenance
Document
1544-1
2.1.2 Outdoor Unit Fault
When the system is switched back on after a power
outage, the Hydraulic Unit may display fault 370 for a
few tens of seconds. This is not a serious problem. It
simply means that the outdoor unit is running its
tests. Once the tests have been completed, the fault
should disappear.
If it doesn't, if a fault has occurred on the outdoor unit
as indicated by the Hydraulic Unit, you must remove
the front (right-hand) facing from the outdoor unit.
Faults are coded by LED flashes. Error messages are
listed in the table below:
On the outdoor unit
When an error occurs:
-
The diode “
ERROR
” (2) blinks
Press once on the switch “
ENTER
” (SW4)
- The
“
ERROR
” (2) diode blinks several times depending on the error’s type
LED display on the outdoor unit (single phase and 3-phase)
LED display
Hydraulic Unit
Diagnosis
Clear
Green
Red
Outdoor unit
Off
Serial reverse transfer error.
1
1 flash
1 flash
1 flash
Serial forward transfer error.
2
4 flashes
1 flash
22 flashes
Heat pump capacity signal error
4
4 flashes 2 flashes 22 flashes
Hydraulic Unit Heat ex. Sensor error
5
6 flashes 3 flashes 18 flashes
Inverter error.
20
Active filter error (single phase)
21
6 flashes 4 flashes 19 flashes
P.F.C. error (3-phase)
27
7 flashes
1 flash
2 flashes
Discharge thermistor error.
7
7 flashes 2 flashes 8 flashes
Compressor thermistor error.
11
5 flashes
Heat-exchange thermistor (intermediate) error.
12
7 flashes 3 flashes
4 flashes
Heat-exchange thermistor (outlet) error.
8
7 flashes 4 flashes 7 flashes
Outdoor temperature thermistor error.
9
7 flashes 7 flashes 9 flashes
Heat sink thermistor error.
10
7 flashes 8 flashes 6 flashes
Expansion valve thermistor error.
14
8 flashes 6 flashes 3 flashes
Pressure sensor error.
24
9 flashes 4 flashes 13 flashes
Current trip (permanent stoppage).
15
14 flashes
Detection of compressor position error (permanent stoppage).
33
9 flashes 5 flashes
15 flashes
Compressor start up error (permanent stoppage).
17
16 flashes
Outdoor unit fan 1 motor error.
9 flashes 7 flashes
17 flashes
Outdoor unit fan 2 motor error.
18
10 flashes
1 flash
11 flashes
Discharge temperature protection (permanent stoppage).
22
10 flashes 3 flashes 12 flashes
Compressor temperature protection (permanent stoppage).
25
10 flashes 5 flashes 20 flashes
Low pressure abnormal.
26
Continuous flashing
Pump down operation.
Continuous
lighting
Off
Defrosting.