Split system (Single phase and 3-phase type)
48
Maintenance
Document
1544-1
COMMAND
LINE
ACCESS
LEVEL
FUNCTION
SETTING RANGE
FACTORY
SETTING
603
U
2
nd
phase on
00:00…--:--
--:--
604 U 2
nd
phase off
00:00…--:--
--:--
605
U
3
rd
phase on
00:00…--:--
--:--
606 U 3
rd
phase off
00:00…--:--
--:--
615
U
Copy
616
U
Default values
No/yes
No
Holidays heating circuit 1
641
U
Preselection
Period 1…8
Period 1
642 U
Period start (Day / Month)
01.01…31.12
643
U
Period end (Day / Month)
01.01…31.12
648 U
Operating level
Frost protection ¦ Reduced
Frost protection
Holidays heating circuit 2
651
U
Preselection
Period 1…8
Period 1
652 U
Period start (Day / Month)
01.01…31.12
653
U
Period end (Day / Month)
01.01…31.12
658 U
Operating level
Frost protection ¦ Reduced
Frost protection
Heating circuit 1
710 U
Comfort setpoint
Reduced temp to
35°C
20°C
712
U
Reduced setpoint
19°C
714 U
Frost protection setpoint
4°C to Reduced
temp
8°C
716
S
Comfort setpoint maximum
20°C…35°C
28°C
720
I
Heating curve slope
0,1…4
0,5
721
I
Heating curve displacement
-4,5°C…4,5°C
0°C
726 I Heating
curve
adaption Off,
on
Off
730
I
Summer/winter heating limit
8°C…30°C
18°C
732
S
24-hour heating limit
-10°C…10°C
-2°C
740
I
Flow temp setpoint min (for fan
convectors)
8°C… 95°C
8°C
741
I
Flow temp setpoint max
8°C… 95°C
55°C
750
S
Room influence
1%...100%
50%
780 S Quick
setback
Off ¦ Down to reduced
setpoint ¦ Down to frost
prot setpoint
Down to reduced
setpoint
790
S
Optimum start control max
0…360min
180 min
791
S
Optimum stop control max
0…360min
60 min
800
S
Reduced setpoint increase start
-30°C…10°C
---
801
S
Reduced setpoint increase end
-30°C…10°C
-5°C
830
S
Mixer valve boost
0…50°C
0
834 S Actuator
running
time
30…873s 240s
850
I
Floor curing function
0…5
Off
851
I
Floor curing setpoint manually
0°C…95°C
25°C
856
I
Floor curing day current
0…32
857
I
Floor curing day completed
0…32
900
S
Optg mode changeover
Protection mode
Cooling circuit 1
901 U Operating
mode
Off ¦ Automatic
Automatic
902
U
Comfort setpoint
15…40°C
24°C
907 U Release
24h/day ¦ Time
program HC ¦ Time
program 5
24h/day
908
I
Flow temp setp at OT 25°C
6…35°C
20°C
909
I
Flow temp setp at OT 35°C
6…35°C
16°C
912
I
Cooling limit at OT
---/8…35°C
20°C
913
S
Lock time at end of heating
---/8…100h
24h
918
S
Summer comp start at OT
20…50°C
26°C
919
S
Summer comp end at OT
20…50°C
35°C
Summary of Contents for Waterstage WO G112LCT Series