476
Upgrade and Maintenance Manual
TX2550 M4
Converting a floorstand model to a rack model
Figure 340: Securing the accessible drive cage (B)
Ê
Carefully turn the server upside down.
I
At least two people are needed to turn over a fully equipped server.
Remove HDDs and PSUs in order to facilitate the task.
Ê
Secure the accessible drive cage with the two screws (see circles) to the
bottom side of the server.
I
Note the correct screw positions: The screw hole on the right that has
been used in the floorstand configuration remains empty.
Ê
Install the front panel module, see section
"Installing the front panel module"
.
Ê
If applicable, install all accessible drives, see section
.
Ê
If applicable, install an HDD extension box, see section
Preparing the intrusion switch
Ê
Remove the intrusion switch module, see section
Ê
Attach a rubber bumper (C26192-Y26-C43) to the front intrusion switch and
reinstall the intrusion switch module, see section
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...