TX2550 M4
Upgrade and Maintenance Manual
359
Processor (CPU)
Never try to fix bent contact springs. Doing so may result in loss of
electrical performance and reliability.
Ê
Confirm that the CPU model number printed on the top of the CPU fits with
the requirements.
Figure 257: Installing the CPU in the CPU frame
Ê
Click the CPU into the CPU frame (see arrows). Make sure that the triangle
marks on CPU (A) and on CPU frame (B) are on the same edge.
Ê
Make sure that the CPU fits in its place.
A
B