![Fujitsu PRIMERGY TX2550 M4 Upgrade And Maintenance Manual Download Page 132](http://html.mh-extra.com/html/fujitsu/primergy-tx2550-m4/primergy-tx2550-m4_upgrade-and-maintenance-manual_121270132.webp)
132
Upgrade and Maintenance Manual
TX2550 M4
Basic software procedures
5.2.18.2 After replacing a system board
I
The following procedure must be done for each system board that is
replaced.
Ê
Confirm with the customer whether the onboard LAN controller you have
replaced has been used as part of a LAN teaming configuration.
Ê
If LAN teaming has been active, you will need to restore the configuration
using the LAN driver utility or OS teaming software.
I
For more information, see the relevant LAN driver manual.
5.2.19 Switching off the ID indicator
Press the ID button on the front panel, or use the iRMC web interface or
ServerView Operations Manager to switch off the ID indicator after the
maintenance task has been concluded successfully.
I
For more information, see section
"Locating the defective server" on
or the "ServerView Suite Local Service Concept (LSC)" and
"iRMC S5 - Web Interface" user guides.
Using the ID button on the front panel
Ê
Press the ID button on the front panel to switch off the ID indicators.
Using the ID icon in the RMC web interface
Ê
Log in to the iRMC S5 web interface.
The icon that represents the ID indicator LED resides on the right of the
menu bar. Its color symbolizes its status:
blue
: the ID LED is on.
grey
: the ID LED is off
Ê
Click the icon to switch the ID indicator LED on or off.
Using ServerView Operations Manager
Ê
In ServerView Operations Manager
Single System View
and press the
Locate
button in the title bar to switch off the ID indicator.
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...