500
Upgrade and Maintenance Manual
TX2550 M4
Appendix A
Indicator
Status
Description
A - Identification
blue on
The server has been highlighted using
ServerView Operations Manager, iRMC web
interface or the ID button on the front panel
for easy identification.
blue flashing
The server has been highlighted for easy
identification using the iRMC (AVR) with
disabled local VGA output.
B - CSS
(Customer Self
Service)
off
No critical event detected (CSS component).
orange on
Prefailure event detected (CSS component).
orange flashing CSS component failure detected.
C - GEL
(Global Error
LED)
off
No critical event detected (non CSS
component).
orange on
Prefailure event detected (non CSS
component).
orange flashing
Non CSS component failure detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server management
software
F - Controller
off
Controller okay
orange on
Controller failure (PCI card installed on
riser card)
G - CPU
off
CPU okay
orange on
CPU failure
H - Memory
off
Memory module running
orange on
Memory module failure
I - iRMC
off
iRMC S5 inactive
green flashing
iRMC S5 okay
K - System fan
off
system fan running
orange on
system fan failure
L - Battery
orange on
Battery failure
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...