TX2550 M4
Upgrade and Maintenance Manual
327
Expansion cards and backup units
9.6.3
Replacing an expansion card in the riser module
Note on network settings recovery
I
When replacing network controllers or the system board, network
configuration settings in the operating system will be lost and replaced
by default values. This applies to all static IP address and LAN teaming
configurations.
Ensure to note down your current network settings before replacing a
controller or the system board.
9.6.3.1
Preliminary steps
Ê
"Locating the defective server" on page 49
Ê
"Disabling the boot watchdog functionality of ServerView Operations
Manager" on page 106
Ê
"Suspending BitLocker functionality" on page 105
Ê
"Shutting down the server" on page 52
Ê
"Disconnecting the power cord" on page 53
Ê
"Getting access to the component" on page 54
Ê
"Locating the defective component" on page 51
Ê
Remove all external cables from the expansion card to be replaced.
Ê
"Removing the riser module" on page 84
9.6.3.2
Removing the expansion card
Ê
Remove the expansion card, see section
from the riser module" on page 325
.
Ê
If the slot bracket on the defective expansion card is to be reused:
"Removing a slot bracket" on page 296
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...