TX2550 M4
Upgrade and Maintenance Manual
129
Basic software procedures
5.2.16 Looking up changed MAC/WWN addresses
When replacing a network controller, the MAC (Media Access Control) and
WWN (World Wide Name) addresses will change.
I
In addition to the procedures described below, MAC/WWN addresses
can also be found on the type label attached to a network controller or
system board.
5.2.16.1 Looking up MAC addresses
Ê
Log in to the ServerView iRMC web interface.
Ê
Open the
Settings
menu.
Ê
Open the
Baseboard Management Controlller
page.
Ê
In the
Network Interface
group, you will find more information on each
network controller in the managed PRIMERGY server, including its MAC
address.
I
This information is only available with the iRMC S5 or above.
Only network controllers supporting the Command Line Protocol
(CLP) will be displayed.
Ê
Inform the customer about the changed MAC address.
5.2.16.2 Looking up WWN addresses
Emulex FC/FCoE adapters
Ê
Enable the network controller’s Option ROM in the BIOS as described in
section
"Enabling Option ROM scan" on page 115
.
Ê
Restart the server.
Ê
During boot, as soon as the Emulex BIOS utility option appears, press
[ALT]
+
[E]
or
[CTRL]
+
[E]
.
Ê
Under
Emulex Adapters in the System
you will find all available Emulex
adapters and their WWN addresses.
Ê
Note down the new 16-digit WWN address.
Ê
Press
[Esc]
to exit the Emulex BIOS utility.
Ê
Inform the customer about the changed WWN address.
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...