TX2550 M4
Upgrade and Maintenance Manual
123
Basic software procedures
5.2.11 Verifying the system time settings
I
This task only applies to Linux and VMware environments.
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
If a Linux/VMware OS is used and the hardware clock has been configured as
UTC (Universal Time, Coordinated) in the operating system, the BMC local time
may not be mapped correctly.
Ê
After replacing the system board, ask the system administrator whether the
RTC or UTC time standard is to be used as system time.
I
If the system time (RTC) is set to UTC, the SEL (System Event Log)
time stamps may differ from the local time.
Ê
Enter the BIOS.
Ê
Select the
Main
menu.
Ê
Under
System Time
and
System Date
specify the correct time and date.
I
By default, the system time set in the BIOS is RTC (Real Time Clock)
local time. If your IT infrastructure relies on universally accepted time
standards, set the
System Time
to UTC (Universal Time, Coordinated)
instead. Greenwich Mean Time (GMT) can be considered equivalent
to UTC.
Ê
Save your changes and exit the BIOS.
I
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
5.2.12 Viewing and clearing the System Event Log (SEL)
5.2.12.1 Viewing the SEL
You can view the System Event Log (SEL) using the ServerView Operations
Manager or the ServerView iRMC web interface:
Viewing the SEL in ServerView Operations Manager
Ê
In ServerView Operations Manager
Single System View
select
Maintenance
from the
Information / Operation
menu.
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...