TX2550 M4
Upgrade and Maintenance Manual
181
Hard disk drive (HDD) / solid state drive (SSD)
Figure 100: Installing the 2.5-inch HDD/SSD module
Ê
Insert the HDD/SSD module into a drive bay and carefully push back as far
as it will go (1).
Ê
Close the locking lever to lock the HDD in place (2).
Ê
When using a RAID array, add the additional HDD/SSD to the RAID array.
I
Configuring the RAID array, refer to the documentation of the RAID
controller, used in your configuration, see section
.
7.3.7.4
Concluding steps
Ê
When working on a floorstand model, close the HDD bay cover, see section
"Installing the drive covers" on page 76
.
7.3.8
Removing 2.5-inch HDD/SSD modules
I
PCIe SSDs SFF are mounted in the same frames as the 2.5-inch
HDD/SSD modules. Therefore, this section is also valid and applicable if
PCIe SSDs SFF are used.
The preliminary and concluding steps are only necessary for HDD/SSD
modules, not for the PCIe SSDs SFF. PCIe SSDs SFF are never
combined in a RAID array.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...