456
Upgrade and Maintenance Manual
TX2550 M4
System board and components
This only indicates that the CPU configuration has been altered.
There is no technical problem.
Please proceed as follows:
Ê
Restart your server.
Ê
As soon as the startup screen appears, press the
[F2]
function
key to enter the BIOS.
If a password is assigned, enter the password and press
[Enter]
.
Ê
Select the
Save & Exit
menu.
Ê
Select
Save Changes and Exit
or
Save Changes and Reset
.
Ê
Verify that the Global Error indicator stops flashing.
Ê
"Updating or recovering the BIOS and iRMC" on page 111
I
When updating to BIOS 1.15.0 or higher with Red Hat Enterprise
Linux 7 as operating system, a network name for onboard LAN,
as well as for the OCP connectors may change.
Inform the customer about the changes.
Ê
If applicable, activate TPM functionality in the system BIOS under
Security
>
TPM (Security Chip) Setting
>
Security Chip
. For more information, see the
corresponding BIOS Setup Utility Reference Manual.
Ê
"Verifying system information backup/restore" on page 113
Ê
"Verifying the system time settings" on page 123
Ê
"Looking up changed MAC/WWN addresses" on page 129
"Updating the NIC configuration file in a Linux and VMware environment" on
page 126
Ê
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...