![Fujitsu PRIMERGY TX2550 M4 Upgrade And Maintenance Manual Download Page 107](http://html.mh-extra.com/html/fujitsu/primergy-tx2550-m4/primergy-tx2550-m4_upgrade-and-maintenance-manual_121270107.webp)
TX2550 M4
Upgrade and Maintenance Manual
107
Basic software procedures
Viewing boot watchdog settings in the iRMC web interface
Ê
Enter the ServerView iRMC web interface.
Ê
Select the
Server Management
menu.
Ê
Under
Watchdog Settings
, you can obtain more information about the current
watchdog status, time out intervals and actions that are triggered if
watchdog time outs are exceeded.
I
For more information on iRMC settings, see the iRMC user guides.
Viewing boot watchdog settings in ServerView Operations Manager
Ê
In ServerView Operations Manager
Single System View
select
Maintenance
from the
Information/Operation
menu.
Ê
Under
ASR&R
select the
Watchdog
tab to obtain more information about the
current watchdog status, time out intervals and actions that are triggered if
watchdog time outs are exceeded.
I
For more information, see the "ServerView Operations Manager - Server
Management" user guide.
5.1.2.2
Configuring boot watchdog settings
If the system is to be started from removable boot media for firmware upgrade
purposes, the Boot watchdog needs to be disabled before starting maintenance
task. Otherwise, the Boot watchdog might initiate a system reboot before the
flash process is complete.
V
CAUTION!
An incomplete firmware upgrade process may render the server
inaccessible or result in damaged/destroyed hardware.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web interface.
Configuring boot watchdog settings in the BIOS
Ê
Enter the BIOS.
Ê
Select the
Server Mgmt
menu.
Ê
Under
Boot Watchdog
set the
Action
setting to
Continue
.
Ê
Save your changes and exit the BIOS.
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...