![Fujitsu PRIMERGY TX2550 M4 Upgrade And Maintenance Manual Download Page 119](http://html.mh-extra.com/html/fujitsu/primergy-tx2550-m4/primergy-tx2550-m4_upgrade-and-maintenance-manual_121270119.webp)
TX2550 M4
Upgrade and Maintenance Manual
119
Basic software procedures
Using the command line interface (Linux/VMware only)
The memory error counter can be reset using the
meclear
utility which is part
of the ServerView agents for Linux.
I
meclear
(Memory Module Error Counter Reset Utility) allows to reset
the error count collected for a memory module, for example after it has
been replaced.
For more Information, see the
meclear
manual pages.
Ê
Log in as root.
Ê
Enter the command below, followed by
[ENTER]
:
/usr/sbin/meclear
Ê
Select the number of a memory module with a status other than "OK" or
"Not available".
Ê
Repeat the step above until all memory modules show the "OK" status.
Ê
Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
5.2.7.2
CPUs
ServerView Operations Manager may report a defective CPU in case of a
critical error.
I
Important note
After replacing a defective CPU, the error counter must be reset
manually using one of the methods below.
Using ServerView Maintenance Tools (Windows only)
Ê
Launch the ServerView Maintenance Tools:
Start
>
Apps
>
Fujitsu
>
Maintenance Tools
Ê
Choose the
CPU
status tab.
Ê
Select the CPU which shows the pre-failure status.
Ê
Click on
Reset Status
.
Ê
Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...