TX2550 M4
Upgrade and Maintenance Manual
157
7
Hard disk drive (HDD) / solid state
drive (SSD)
Safety notes
V
CAUTION!
●
Before removing several HDD/SSD modules, make sure that all
HDD/SSD modules can be reinstalled into their original bay.
Otherwise, data may be lost.
●
Do not touch the circuitry on boards or soldered parts. Hold circuit
boards by their metallic areas or edges.
●
Before removing an HDD, wait for about 30 seconds until the disk has
stopped spinning completely.
●
When an HDD is starting up, a resonant noise may be audible for a
short while. This does not indicate a failure.
●
Depending on the operating system, you can configure the write
cache settings for the HDDs. If a power failure should occur while the
write cache is enabled, cached data may be lost.
●
When disposing of, transferring, or returning an HDD or SSD, wipe
out the data on the drive for your own security.
●
Rough handling of HDDs may damage the stored data. To cope with
any unexpected problems, always back up important data. When
backing up data to another HDD, you should make backups on a file
or partition basis.
●
Be careful not to hit the HDD or bring it into contact with metallic
objects.
●
Handle the HDD and SSD on a shock and vibration free surface.
●
Do not use the HDD and SSD in extremely hot or cold locations, or
locations with extreme temperature changes.
●
Never attempt to disassemble the HDD or SSD.
●
For more information, see chapter
.
Summary of Contents for PRIMERGY TX2550 M4
Page 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Page 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Page 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Page 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Page 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Page 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Page 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Page 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Page 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Page 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...