11.3
Front panel cable
11.3.1
Replacing the left front panel cable
Field Replaceable Unit
(FRU)
Hardware: 30 minutes
Tools:
Preliminary and concluding steps: Phillips PH2 / (+) No. 2
Main steps: tool-less
Preliminary steps
▶
"Shutting down the server" on page 41
.
▶
"Disconnecting the power cord" on page 42
.
▶
If the server node is installed in server node bay 2, remove it, see
"Removing server nodes from the server enclosure" on page 43
.
▶
If applicable, remove the front bezel, see
▶
If applicable, remove the HDD/SSD modules until slot 6 from the left from
the relevant HDD/SSD cage, see
"Removing a 2.5-inch HDD/SSD module"
.
▶
If applicable, remove the 2.5-inch HDD/SSD dummy modules until slot 6
from the left from the relevant HDD/SSD cage, see
HDD/SSD dummy module" on page 113
▶
"Extending the server enclosure out of the rack" on page 49
.
▶
If applicable, remove the front bezel mounted on the left end, see
"Removing the HDD/SSD x6 front bezel" on page 140
▶
If applicable, remove the front bezel mounted on the left end, see
"Removing the HDD/SSD x4 front bezel" on page 141
▶
"Removing the top covers" on page 54
.
▶
Remove the high speed riser module on the left side, see
defective high speed riser module" on page 151
.
Front panel
CX400 M6
Upgrade and Maintenance Manual