CHAPTER 10 Expansion File Unit Type-2
10.3
Preparations for Use
This section describes the following:
Installation notes
Installation specifications
10.3.1
Installation notes
CAUTION
Unit Damage
If the following notes are not observed the Expansion File Unit Type-2 may be
damaged. Be sure to follow these notes.
Rack installation notes
The following installation instructions are intended to provide product safety requirements to be
addressed when the end-use product manufacturer installs this product in their equipment.
As the Expansion File Unit Type-2 is installed in a closed or multi-unit rack assembly, the
operating ambient temperature inside of the rack environment may be greater than the room
temperature. So, consideration should be given to installing the Expansion File Unit Type-2 in
an environment compatible with the manufacturer’s maximum rated ambient temperature.
–
Consideration for adjustment of air conditions like air circulation should be given to
prevent the internal rack ambient temperature from exceeding the maximum operating
temperature of this unit.
–
Maximum internal operating temperature of this unit: 35 deg. C (95 deg. F)
Installation of the Expansion File Unit Type-2 should be such that the amount of air flow
required for safe operation of the Expansion File Unit Type-2 is not compromised.
–
The Expansion File Unit Type-2 has ventilation openings at the front and rear faces of the
unit.
–
To prevent overheating, do not cover or close these ventilation openings.
Mounting of the Expansion File Unit Type-2 in the rack should be such that a hazardous
condition does not result from uneven mechanical loading. To maintain the stability of the
entire rack, please fix the rack to the wall or floor by suitable means.
–
Be careful of injuries during installation of the Expansion File Unit Type-2 into the rack.
–
Do not install the Expansion File Unit Type-2 into a rack if the server unit may make the
entire rack unstable.
–
Maximum configured weight of this unit: 30 kg (66.14 lb.)
If the Expansion File Unit Type-2 is supplied with power from a power strip or service outlet of
other units, it may overload the power supply cord or the power strip of other units.
180
Summary of Contents for Primepower200
Page 1: ...P321 E122 04EN PRIMEPOWER PRIMEPOWER200 PRIMEPOWER400 PRIMEPOWER600 ...
Page 2: ......
Page 12: ......
Page 116: ......
Page 142: ......
Page 192: ......
Page 254: ......
Page 255: ...12 RCI Commands CONTENTS 12 1 Overview 228 12 2 RCI Commands 228 227 ...
Page 258: ......
Page 266: ......
Page 267: ...14 Glossary CONTENTS 14 1 Glossary 240 239 ...
Page 272: ......