11.4 DAT Drive (DDS4)
11.4.6
Write-protecting a data cartridge
Data cartridges have a write-protection tab to protect important data from being overwritten by mistake.
Write-protection Tab
Read Only
Write Enabled
Figure 11.6
DAT Data Cartridge Write-protection Tab
11.4.7
Loading a data cartridge
1
Check that the Tape LED and Clean LED are both out.
When the Tape LED is lit, this means that a data cartridge is already inserted.
2
Placing it against the shutter, insert the data cartridge straight into the DAT drive.
Once the data cartridge is partially inserted, it will be automatically drawn into the DAT drive.
3
When loading of the tape is complete, the Tape LED lights to indicate that DAT drive is ready for accessing.
11.4.8
Ejecting a data cartridge
1
Check that the Tape LED is not blinking (the DAT drive is not operating).
2
Press the Eject button.
The tape is rewound and unloaded. The Tape LED will blink during this operation.
When the tape has finished being rewound, the shutter automatically opens, and the data cartridge is ejected.
It can take up to 120 seconds for a data cartridge to be ejected. After the tape is ejected, the Tape LED goes
out.