CHAPTER 9 Expansion Disk Cabinet
(2) RCI connector
Use the RCI cable provided with the Expansion Disk Cabinet to connect it to the PRIMEPOWER
Server. The RCI splitter/connector should be used to attach the RCI cable.
A terminator must also be connected.
The appropriate RCI commands must be issued to add/set-up an Expansion Disk Cabinet.
(3) AC power input
Connect the power cable to this point.
(4) AC main line switch
CAUTION
Data destruction
Never turn the AC main line switch or disconnect the power cable
while the Expansion Disk Cabinet is turned on. If you do so, data in
the disk drive may be lost.
This is the main power supply switch and should normally be left in the "
|
" position.
In this position the Expansion Disk Cabinet is slaved to the PRIMEPOWER Server’s power supply
and will be turned on and off by commands from the Server.
If set to the "
O
" position, the Expansion Disk Cabinet will not turn on when the PRIMEPOWER
Server is started up.
170