10.3 Preparations for Use
–
Confirm that the current rating of the power strip or service outlet exceeds the combined
ratings of all equipment it is supplying.
–
Electrical ratings of this unit: Rated 100 to 240VAC, 3.0 to 1.5A, 50/60Hz, single-phase
Reliable earthing of rack-mounted equipment should be maintained. Particular attention should
be given to non-direct-to-mains connections (e.g. via power strips, etc.).
CAUTION
Connect the ground before connecting any of the power supply
lines. If all of the power cables from the Expansion File Unit Type-2
are connected to a single power strip, high leakage current
exceeding the stipulated value may leak through to the earth lead
of the power strip.
If the power strip is not directly connected to the main distribution
panel, use a power strip with an industrial plug.
General installation notes
Do not block the ventilation holes.
Do not install the Expansion File Unit Type-2 where it will be exposed to sunlight or sources of
heat.
Do not install the Expansion File Unit Type-2 in dusty places or places where it will be exposed
to corrosive gases or sea breezes.
Keep the Expansion File Unit Type-2 isolated from vibration. Install the Expansion File Unit
Type-2 on a level surface so that it does not tilt.
Make sure that the AC power supply source is grounded properly using a maximum resistance
of 100 Ohms. Also, do not ground the AC power supply source using a shared ground. Use only
an independent grounding point. Otherwise, the Expansion File Unit Type-2 may malfunction.
Do not run a cable under a unit or allow a cable to become taut. Do not disconnect the power
cable when the power is on.
Do not place anything on the Expansion File Unit Type-2. Do not use the top of the Expansion
File Unit Type-2 as a workspace.
To prevent condensation in the Expansion File Unit Type-2, do not raise the ambient room
temperature rapidly in winter.
Use the Expansion File Unit Type-2 only after it has warmed up sufficiently.
Do not install the Expansion File Unit Type-2 near EM noise generating devices such as
photocopiers, air conditioners, or welders.
Take electrostatic prevention measures. Note that some carpets generate static electricity easily
and can cause the Expansion File Unit Type-2 to malfunction.
When moving the Expansion File Unit Type-2, do not pull on the front cover. Otherwise, the
Server may be damaged.
The unit does not support dual AC power input / feed, even if both power cards come from the
unit.
Both AC power cords must be plugged into the same power grid / circuit.
181
Summary of Contents for Primepower200
Page 1: ...P321 E122 04EN PRIMEPOWER PRIMEPOWER200 PRIMEPOWER400 PRIMEPOWER600 ...
Page 2: ......
Page 12: ......
Page 116: ......
Page 142: ......
Page 192: ......
Page 254: ......
Page 255: ...12 RCI Commands CONTENTS 12 1 Overview 228 12 2 RCI Commands 228 227 ...
Page 258: ......
Page 266: ......
Page 267: ...14 Glossary CONTENTS 14 1 Glossary 240 239 ...
Page 272: ......