8.3 Preparations for Use
Table 8.3
Installation Specifications of the PRIMEPOWER600 Rackmount (10U) Server (2/2)
778 (*1) (D)
(31 in.)
Unit Side
Item
Specification
Unit Dimensions
(units : mm)
Unit Front
445 (*1) (W)
(18 in.)
440 (H)
(17 in.)
Service Areas
(units : mm)
Unit
Top
Side
Service
Area
Rear
Service
Area
Front
Service
Area
800
(32 in.)
930 (*2)
(36 in.)
550
(21 in.)
800
(32 in.)
Front
Service
Area
800
(32 in.)
650 (*2)
(25 in.)
Pull-Out
Area
(*1)
600
(23 in.)
*1:
Not including any projections.
*2:
Keep the pull-out area clear so that units inside the PRIMEPOWER600 Rackmount (10U) Server
can be pulled out from the rack cabinet when performing maintenance.
*3:
When a GP7B7RK3x/RK4x rack cabinet is used
8.3.3
Connecting the console
A device terminal such as a personal computer must be connected to the serial port to act as the console for
PRIMEPOWER600 Rackmount (10U) Servers to which a display or keyboard are not connected. Pay attention to
the following when connecting the console to the serial port on the PRIMEPOWER600 Rackmount (10U) Server.
Connecting the serial cable:
Connect to serial A port.
Communication settings on the terminal:
Set to 8 bits, 1 stop bit, parity OFF, and 9600 baud.
149
Summary of Contents for Primepower200
Page 1: ...P321 E122 04EN PRIMEPOWER PRIMEPOWER200 PRIMEPOWER400 PRIMEPOWER600 ...
Page 2: ......
Page 12: ......
Page 116: ......
Page 142: ......
Page 192: ......
Page 254: ......
Page 255: ...12 RCI Commands CONTENTS 12 1 Overview 228 12 2 RCI Commands 228 227 ...
Page 258: ......
Page 266: ......
Page 267: ...14 Glossary CONTENTS 14 1 Glossary 240 239 ...
Page 272: ......