CHAPTER 5 PRIMEPOWER400 Rackmount (4U) Server
5.3.6
Installing the Enhanced Support Facility package
CAUTION
Data Destruction
Install the "Enhanced Support Facility" before using the system. Without this
package, a front panel-miss operation or hardware error may cause the system
to shutdown or data to be lost.
With the PRIMEPOWER servers, be sure to install all of the programs provided with the "Enhanced Support
Facility" to ensure the high reliability functions or the service processor. For details, refer to the "User’s Guide"
included with the "Enhanced Support Facility."
5.3.7
How to enable/disable the break signal
CAUTION
Data Destruction
If improper commands are used at the ok prompt, data may be lost. If you need
to use any command except those shown in this manual, you should fully
understand the function and usage of the command before using it.
Data is sometimes lost as the bootup sequence shifts to display of the ok prompt during system operation in
response to a break signal from the console terminal connected to the serial port or the STOP+A command from
the keyboard.
To prevent this kind response to a break signal arriving from the serial port or the STOP+A command from the
keyboard, make the following settings using the set-fw-options command shown below with the ok prompt
displayed on screen, and then set the MODE switch on the control panel to the SECURE mode.
How to disable the break signal and STOP A command
1
Use the print-fw-options command to check the current setting.
The factory default is that nothing is set.
ok
print-fw-options
fw-options =
80
Summary of Contents for Primepower200
Page 1: ...P321 E122 04EN PRIMEPOWER PRIMEPOWER200 PRIMEPOWER400 PRIMEPOWER600 ...
Page 2: ......
Page 12: ......
Page 116: ......
Page 142: ......
Page 192: ......
Page 254: ......
Page 255: ...12 RCI Commands CONTENTS 12 1 Overview 228 12 2 RCI Commands 228 227 ...
Page 258: ......
Page 266: ......
Page 267: ...14 Glossary CONTENTS 14 1 Glossary 240 239 ...
Page 272: ......